Industrial Smart PDU 0U Rack Mount 32A 3 Phase Power Distribution - China Suppliers & Factory Solutions
Performance And Advantages
- The MPS XPDU can monitor and remotely control the power voltage and load current via IP, and display various power parameters locally.
- Additionally, the MPS XPDU can issue alerts for overvoltage, undervoltage, overload, etc., and set alarm thresholds through the upper-level monitoring platform.
- Moreover, the PDU can also statistically analyze active power, apparent power, power factor, energy consumption and other power parameters, meeting the requirements for PUE statistics in the computer room, and display and store the data through the upper-level monitoring platform.
- Compared with existing PDUs, the performance has been largely optimized.
Application Scope
Used for IT power supply at the cabinet level, currently mainly targeted at data center applications. The following five major application scenarios are as follows:
- Cloud computing / billing / AI hosting and other IDC centers
- When the cabinet heat density is high (898KW/Rack)
- When it is necessary to know the PUE of the cabinet
- When a large number of blade servers are used in the cabinet
- When remote management is required
Technical Features
- Electric energy metering and remote control to turn off and on each socket
- Alarm threshold setting function: Through the system interface, the upper and lower limit values of the total load current can be custom set
- System alarm function: When the total load current exceeds the alarm threshold setting value or a system fault occurs, an automatic alarm will be triggered
- Cascading function: Supports background communication cascading, with a maximum of 4 cascades
Technical Features
- Sequential start function: By default, it supports a 1-second sequential start interval, and the interval start delay can be modified through the upper-level monitoring platform
- Remote on/off function: Can remotely turn off the connected devices
- Simplified cascading operation - Localized address setting
- Provides vertical installation products, not occupying the horizontal installation space of the cabinet
Frequently Asked Questions
What parameters can the MPS XPDU monitor and control?
The MPS XPDU can monitor and remotely control the power voltage and load current via IP. It also displays various power parameters locally and analyzes active power, apparent power, power factor, and energy consumption.
How does the system handle power alerts and thresholds?
The MPS XPDU can issue automatic alerts for overvoltage, undervoltage, and overload. Users can custom set the upper and lower limit values of the total load current as alarm thresholds through the system interface or upper-level monitoring platform.
What are the primary application scenarios for the MPS XPDU?
It is mainly used for cabinet-level IT power supply in data centers. Key scenarios include cloud computing/billing/AI hosting in IDC centers, high cabinet heat density (898KW/Rack), PUE tracking, blade server cabinets, and environments requiring remote management.
Does the PDU support cascading configuration?
Yes, it supports background communication cascading with a maximum of 4 cascades. It also features localized address setting to simplify the cascading operation.
What is the sequential start function?
By default, the PDU supports a 1-second sequential start interval when powering on devices. This interval start delay can be adjusted through the upper-level monitoring platform to protect system stability.
How does the physical installation design save cabinet space?
The PDU provides vertical installation configurations, allowing it to be mounted in the cabinet without occupying the valuable horizontal (U-space) installation areas.