China Orient Smart Lock IP68 LV Switchgear Cabinet PDU - High-quality Suppliers and Factory Solutions
Selling Points
Ultra-Fast Switching
Intelligent Monitoring & Protection
- Real-time monitoring of voltage and frequency for dual power sources
- Integrated protection mechanisms against overvoltage/undervoltage, overload, short circuits, and other anomalies
- Equipped with an LCD display for intuitive access to power status and fault diagnostics
High Reliability
Flexible Adaptability
Application Scenarios
- IT rooms and data centers (servers, storage devices)
- Communication base stations and financial data centers
- Precision laboratories and medical equipment
- Industrial automation control centers
Tech Specification
| Category | Parameter | Specification | Verification |
|---|---|---|---|
| Power Input | Voltage / Frequency | 200-240V AC ±15% / 50-60Hz ±3Hz | IEC 62040-3 |
| Connectors | Dual IEC 60320 C20 (16A per input) | UL 498 Certified | |
| Power Output | High-Power Ports | 2× C19 (16A each) | Max 3,680W per port |
| Branch Ports | 6× C13 (10A each) | Total capacity: 3.8kVA | |
| Switching | Transfer Time | ≤4ms | Oscilloscope verified |
| Transfer Conditions | >15% voltage deviation / >±0.5Hz freq. error / Manual override | Zero-crossing detection | |
| Monitoring | Parameters | Voltage, Current, kW/kVA/kVAR, PF, Frequency, Energy (kWh) | ±0.5% accuracy |
| Sampling Rate | 128 samples/cycle | Real-time waveform capture | |
| Communication | Protocols | SNMP v3, Modbus-TCP/RTU, SSH, Telnet, Custom TCP | TLS 1.2 encrypted |
| Ports | 1× RS485 (cascading), 1× USB (firmware), RJ45 (10/100M Ethernet) | Supports ≤32 cascaded units | |
| Control | Load Management | Per-output remote ON/OFF + Sequential startup | Web/CLI interface |
| User Access | Admin/Operator/Viewer roles with audit logging | RBAC support | |
| Protection | Electrical Safety | 6kV surge suppression / 10kA SCCR / Input OVP-UVP | UL 1008, EN 61643-11 |
| Mechanical | Form Factor | 1U Rack-mountable (44H × 483W × 260D mm) | Steel enclosure, IP20 |
| Cooling | Dual independent fan modules (N+1 redundancy) | Hot-swappable | |
| Environmental | Operating Temp | 0°C to 40°C (derate 2.5%/°C above 35°C) | IEC 62040-1 |
| Compliance | Standards | IEC 62040, UL 1008, CE, RoHS, EN 55032 Class A (EMC) | Full test repo |
Exhibition Show
Long been dedicated to the R&D and production of PDUs for IDC (Internet Data Center). Since 2015, we have set up a R&D center and an independent electrical laboratory to meet various complex product experimental tests. Our R&D team consists of a number of senior engineers in hardware, software and mechanics, which develop common PDUs and intelligent PDUs to meet different market and customer needs. As of now, we have obtained two invention patents, nine utility model patents, seven appearance patents and four software copyrights.
Specializes in the sheet metal processing of PDU metal housings, server chassis and power supply chassis.
Focuses on the R&D, design, production and sales of intelligent home appliances, and is committed to creating a safe, convenient and comfortable future living space for users.
Frequently Asked Questions
A: The transfer switching time is ≤4ms, which is oscilloscope verified. This ensures a seamless power transition that protects servers and precision equipment from downtime.
A: It supports a wide range of protocols including SNMP v3, Modbus-TCP/RTU, SSH, Telnet, and Custom TCP, all secured with TLS 1.2 encryption.
A: The input features dual IEC 60320 C20 ports (16A per input). The output features 2× C19 high-power ports (16A each) and 6× C13 branch ports (10A each), with a total capacity of 3.8kVA.
A: Yes, it supports per-output remote ON/OFF control and sequential startup management via Web or CLI interfaces with Role-Based Access Control (RBAC).
A: The system includes 1× RS485 port dedicated to cascading, which supports linking up to 32 units for centralized management.
A: The product complies with major international standards including IEC 62040, UL 1008, CE, RoHS, and EN 55032 Class A (EMC).